XLPE Insulated Mining Power Cable
  • XLPE Insulated Mining Power CableXLPE Insulated Mining Power Cable
  • XLPE Insulated Mining Power CableXLPE Insulated Mining Power Cable
  • XLPE Insulated Mining Power CableXLPE Insulated Mining Power Cable

XLPE Insulated Mining Power Cable

Qiancheng XLPE Insulated Mining Power Cable complies with MT/T 818 standard. It features high-purity copper conductor, XLPE insulation and flame-retardant PVC sheath. Heat-resistant and durable for various fixed power distribution in mines. Complete traceable qualifications available, in-stock products and custom options are supported.

Model: MYJV, MYJV22.

XLPE Insulated Mining Power Cable conforms to MT/T 818.13-2009, with high-purity oxygen-free copper conductors, XLPE cross-linked insulation and a flame-retardant PVC sheath. Rated voltage ranges from 0.6/1kV to 8.7/10kV, with a long-term operating temperature of 90℃. The cable is intended for fixed power distribution in underground and open-pit coal mines. It is for static installation and should not be used on mobile equipment that requires continuous dragging or repeated bending.

XLPE Insulated Mining Power Cable

Product Specifications and Technical Parameters Table

Parameter Category

Parameter Item

Technical Index

 

Structure Configuration

Conductor Material

High-purity oxygen-free copper; available in single-core solid conductor / multi-stranded flexible conductor

 

Conductor Cross-section

2.5 mm²~300 mm²

 

Insulation Layer

XLPE cross-linked polyethylene insulation

 

Armour Layer (Optional)

Steel-tape armouring

 

Outer Sheath

PVC polyvinyl chloride sheath; oil-resistant, acid-alkali-resistant and flame-retardant

 

Core Configuration

3-core or 3+1-core optional

 

Electrical Performance

Rated Voltage

0.6/1 kV~8.7/10 kV

 

Power-frequency Voltage Withstand

Pass AC voltage test without breakdown within 5 minutes

 

Conductor DC Resistance

Meets requirements of MT 818 or GB/T 3956 standards

 

Flame-retardant Performance

Fire-resistance Grade

Satisfies fire-resistance requirements for mine working conditions; reliable power-on in short-term high-temperature environment

 

Flame-retardant Grade

Complies with MT 386 mine-used flame-retardant standard; self-extinguishing upon flame removal

 

Key Construction Features

1. XLPE Insulation for Higher Operating Temperatures

The XLPE insulation has a specified long-term operating temperature of 90℃, with a short-duration short-circuit temperature of up to 250℃. Compared with PVC insulation, XLPE provides a higher temperature rating for fixed power circuits where conductor loading and ambient conditions need to be considered together.

2. Copper Conductor and Electrical Performance

The conductor is made from high-purity oxygen-free copper and is available in solid or stranded construction according to the cable specification. Conductor cross-section, core arrangement and rated voltage should be matched with the connected load, transmission distance and installation conditions. DC conductor resistance is checked against the applicable MT 818 or GB/T 3956 requirements.

3. Flame-Retardant PVC Sheath

The outer sheath provides the cable's external protection and incorporates flame-retardant properties for mining applications. The supplied specification also identifies resistance to oil and acid-alkali exposure. Actual chemical exposure, water conditions, temperature and mechanical stress should be considered when confirming the appropriate sheath construction.

4. Optional Steel-Tape Armour

For installations where additional mechanical protection is required, a steel-tape armoured construction is available. MYJV22 is therefore differentiated from the unarmoured MYJV construction by its armour layer. The final construction should be selected according to the laying method, mechanical risk and applicable project specification.

Installation and Application Conditions

This cable range is intended for fixed power distribution rather than continuous mobile service. Typical applications include underground main roadways, electromechanical chambers, fixed pump systems, ventilation equipment, conveyor power circuits and other stationary mine power-distribution points.

1. Underground Fixed Power Distribution

For underground installations, the cable specification should be checked against rated voltage, load current, installation route, ambient temperature, moisture exposure and available mechanical protection. Where the cable is routed through areas with a higher risk of impact or compression, an armoured construction may be considered.

2. Open-Pit Mine Power Systems

Fixed circuits in open-pit mines can involve outdoor exposure, dust, rain and temperature changes. Cable selection should account for these environmental conditions together with the required voltage level, conductor size and laying arrangement.

3. Coal-Washing and Supporting Facilities

Fixed power circuits for coal-washing plants, pump rooms, ventilation systems and other supporting facilities can be specified according to the equipment load and distribution distance. The cable construction should be checked for the actual environment rather than applying one specification to all mine facilities.

XLPE Insulated Mining Power Cable

Technical Selection and Inspection

Before ordering, the required rated voltage, conductor cross-section, number of cores, armour construction, cable length and installation method should be confirmed. For longer power-supply routes, voltage drop and conductor resistance should also be considered together with the expected load.

For incoming inspection, the product model and cable construction can be checked against the purchase specification. Depending on the project requirements, documentation and test records may include conductor resistance, insulation-related tests, voltage withstand results and flame-retardant test records. Where mine-specific certification or additional inspection documents are required, these should be confirmed before production and shipment.

FAQ

Q1: What standard applies to this mining power cable?

A: The product is specified according to MT/T 818.13-2009, with conductor requirements referenced to GB/T 3956 where applicable. The exact standard and documentation required for a project should be confirmed against the selected model and rated voltage.

Q2: What voltage and conductor sizes are available?

A: The listed rated-voltage range is 0.6/1 kV to 8.7/10 kV, while the technical table lists conductor cross-sections from 2.5 mm² to 300 mm². Core configuration can be 3-core or 3+1-core, with the exact combination depending on the selected cable specification.

Q3: What is the difference between MYJV and MYJV22?

A: MYJV refers to the XLPE-insulated, PVC-sheathed construction, while MYJV22 adds steel-tape armouring. The armoured version is considered where the installation requires additional mechanical protection. The appropriate construction depends on the cable route and laying conditions.

Q4: Can this cable be used on coal shearers or other mobile mining equipment?

A: No. This cable is intended for static installation and fixed power distribution. Equipment involving continuous dragging, repeated bending or other mobile service normally requires a flexible mining cable specifically specified for that operating condition.

Q5: What information should be provided when requesting a quotation?

A: The required information normally includes rated voltage, conductor cross-section, core configuration, cable length, quantity, installation method and application equipment. If the project requires specific certification, inspection records, packing requirements or technical documents, these should also be stated in the inquiry.

Q6: What should be checked before shipment or site acceptance?

A: Check the cable model, rated voltage, conductor size, core configuration, armour type and cable length against the purchase specification. Depending on the project, review the relevant electrical test results, conductor resistance data, voltage withstand records, flame-retardant documentation and required certificates before acceptance.

For fixed mine power-distribution systems, XLPE Insulated Mining Power Cable should be selected according to electrical load, rated voltage, installation method and environmental conditions. For applications involving continuous movement, the cable construction should be reviewed separately to match the mechanical requirements of the equipment.