Aluminum XLPE FR Low Voltage Power Cable
  • Aluminum XLPE FR Low Voltage Power CableAluminum XLPE FR Low Voltage Power Cable
  • Aluminum XLPE FR Low Voltage Power CableAluminum XLPE FR Low Voltage Power Cable
  • Aluminum XLPE FR Low Voltage Power CableAluminum XLPE FR Low Voltage Power Cable

Aluminum XLPE FR Low Voltage Power Cable

Qiancheng Aluminum XLPE FR Low Voltage Power Cable is a lightweight fire-resistant cable. Factory direct spot shipment. Purchasers are welcome for consultation.

Aluminum XLPE FR Low Voltage Power Cable is supplied in bulk from original factory stock. It is a cost-effective cable for civil and industrial power distribution. It integrates lightweight structure with dual protection of flame retardancy and fire resistance, balancing cost advantages and fire-safety standards. It is the preferred cable for low-voltage fire-emergency circuits.

Aluminum XLPE FR Low Voltage Power Cable

Product Dimensions and Technical Parameters

Nominal cross-section

(mm²)

Insulation thickness

(mm)

Sheath thickness

(mm)

Approximate cable outer diameter

(mm)

Conductor DC resistance

(Ω/km)Al

 

Test voltage

(kV/5min)

Ampacity in air (A)-Al

(A)-Al

Ampacity in direct-buried soil(A)-Al

1×1.5

0.7

1.5

6

—

3.5

—

—

1×2.5

0.7

1.5

6

≤12.1

3.5

26

32

1×4

0.7

1.5

7

≤7.41

3.5

35

42

1×6

0.7

1.5

7

≤4.61

3.5

45

54

1×10

0.7

1.5

8

≤3.08

3.5

59

69

1×16

0.7

1.5

9

≤1.91

3.5

78

90

1×25

0.9

1.5

10

≤1.20

3.5

100

115

1×35

0.9

1.5

12

≤0.868

3.5

125

135

1×50

1.0

1.5

13

≤0.641

3.5

150

165

1×70

1.1

1.5

14

≤0.443

3.5

190

200

1×95

1.1

1.5

16

≤0.320

3.5

230

240

1×120

1.2

1.5

18

≤0.253

3.5

370

275

1×150

1.4

2.0

21

≤0.206

3.5

310

310

1×185

1.6

2.0

23

≤0.164

3.5

360

355

1×240

1.7

2.0

25

≤0.125

3.5

430

410

1×300

1.8

2.0

34

≤0.100

3.5

495

465

1×400

2.0

2.1

37

≤0.0778

3.5

590

535

1×500

2.2

2.2

41

≤0.0605

3.5

685

610

1×630

2.4

2.3

45

≤0.0469

3.5

800

695

1×800

2.6

2.4

46

≤0.0367

3.5

930

785

1×1000

2.8

2.6

51

≤0.0291

3.5

1050

875

Core Advantages Compared with Peer-level Products

Lower Overall Procurement Cost

Aluminum-conductor cables reduce self-weight by about 30 %, lowering material, cross-border logistics and installation labor costs, which helps control infrastructure budgets for long-distance municipal projects. Unlike ordinary aluminum cables on the market with simplified fire-resistant structures, this product is equipped with a complete double-layer mica fire-resistant layer, balancing cost-performance and fire-protection requirements.

Superior High-temperature Resistance & Durability

Adopting XLPE insulation, it features higher temperature resistance, acid-alkali resistance and anti-ageing performance, delivering longer service life under outdoor and cable-trench conditions and reducing later-stage maintenance and replacement costs.

Dual Protection of Flame Retardancy & Fire Resistance with Verified Performance

Tested by third-party laboratories: it can maintain continuous power supply for 90 minutes under 750 ℃ open-flame environment, and the outer sheath extinguishes rapidly upon flame removal. Validated by numerous overseas fire-renovation projects, it achieves a higher pass-through rate for fire-supervision acceptance.

Aluminum XLPE FR Low Voltage Power CableAluminum XLPE FR Low Voltage Power Cable

Three-level Safety Performance

Fire Safety

Aluminum XLPE FR Low Voltage Power Cable has built-in double-layer mica fire-resistant structure. Under high-temperature conditions, the mica layer sinters to form a heat-insulating barrier. It sustains power supply for 90 minutes under 750 ℃ open flame to guarantee normal operation of emergency lighting, fire-fighting pumps and alarm devices. The flame-retardant outer sheath achieves self-extinguishing upon flame removal and inhibits fire spread along cable trays. Its eco-friendly flame-retardant formulation produces low-smoke low-toxic combustion fumes to reduce suffocation risks in fire scenarios and complies with fire-safety codes for public buildings.

Electrical Safety

High-purity aluminum conductors deliver stable resistivity. 20 ℃ DC resistance is kept within standard range with controllable temperature rise during long-term operation. XLPE insulation features uniform thickness without eccentricity. All finished cables pass power-frequency withstand-voltage and insulation-resistance tests and maintain stable insulation performance under complex conditions such as humid cable trenches and outdoor overhead laying, minimizing electric-leakage and short-circuit faults. Long-term field tests in multiple overseas municipal projects show significantly lower circuit-failure rate compared with non-standard aluminum-conductor cables.

Personal Safety

The cable outer sheath is wear-resistant and extrusion-resistant, not easy to damage during construction pulling and bending, lowering on-site electric-shock hazards. Raw materials contain no heavy-metal hazardous substances and produce no highly corrosive flue gas in fire. Durable fire-retardant and fire-resistant performance prevents spontaneous combustion caused by overload or ageing. It is suitable for high-occupancy venues including schools, hospitals and residential areas, with proven long-term safe-operation records from multiple implemented projects.

Laying Instructions

1.Minimum ambient laying temperature ≥ 0 ℃. It is recommended to pre-warm cables indoors before construction under low-temperature conditions to prevent sheath embrittlement and cracking.

2.Applicable scenarios: indoor fire-protection cable trays, outdoor overhead laying, cable trenches, mild direct burial in soil.

3.Long-term underwater immersion laying is prohibited.

4.Special aluminum terminals must be adopted for aluminum-conductor connections. Joints shall be sealed with matching fire-resistant heat-shrinkable sleeves to guarantee flame-retardant and fire-resistant performance at joints.

5.Integrated fire-proof structure. No additional on-site wrapping with fire-proof coil materials is required, effectively shortening construction periods.

FAQ

Q1:What are the main differences between this aluminum fire-resistant cable and ordinary aluminum cables?

A:It is about 30 % lighter than copper-conductor cables of the same specification, cutting material, logistics and installation labor costs. It retains complete double-layer mica fire-resistant layers, unlike some aluminum cables on the market with simplified fire-resistant structures, balancing cost and fire-safety standards.

Q2:What performance indicators can the cable achieve for power supply under fire conditions?

A: Third-party tests verify that it can maintain continuous power supply for 90 minutes under 750 ℃ open-flame environment to keep fire-fighting pumps, emergency lighting and other equipment running. The sheath self-extinguishes rapidly after flame removal, facilitating project fire-safety acceptance.

Q3:What improvements does XLPE insulation bring to cable durability?

A: XLPE insulation features high temperature resistance, acid-alkali resistance and anti-ageing performance. It adapts to outdoor and cable-trench environments with longer service life and reduces investment for later-stage maintenance and cable replacement.

Q4:How is the electrical stability of the aluminum fire-resistant cable?

A: DC resistance of high-purity aluminum conductors complies with standards with controllable temperature rise. XLPE insulation has uniform thickness. Finished cables pass power-frequency withstand-voltage and insulation-resistance tests. Insulation performance remains stable under humid and overhead laying conditions, lowering risks of electric leakage and short-circuit.

Q5:What restrictions apply to low-temperature construction and laying environments for this cable?

A: Laying ambient temperature should not be lower than 0 ℃. Pre-heating is recommended for low-temperature construction. It supports tray laying, overhead installation, cable-trench laying and mild direct burial. Long-term underwater immersion is not allowed.

Q6:What special notes apply to aluminum-conductor connection construction?

A: Special aluminum terminals must be selected for connections. Joints shall be sealed with fire-resistant heat-shrinkable sleeves to guarantee fire-retardant and fire-resistant performance at joints. Copper terminals shall not be used directly in substitution.

Q7:Is additional on-site wrapping with fire-proof coil materials required during construction?

A: The cable adopts integrated fire-proof structure. No extra on-site fire-proof coil wrapping is needed, simplifying working procedures and shortening overall construction duration.

Q8:What personal-safety guarantees are available for application in high-occupancy public venues?

A: The sheath is wear-resistant and extrusion-resistant and not easy to damage during pulling and bending. Raw materials contain no heavy-metals and produce low-smoke low-toxic combustion fumes. It resists spontaneous combustion caused by overload and ageing, making it suitable for venues such as hospitals, schools and residential areas.


Hot Tags: aluminum xlpe fr low voltage power cable, xlpe insulated aluminum power cable, fire resistant low voltage cable
Send Inquiry
Contact Info

Looking for the right cable for a project or application? Send your requirements to Qiancheng Cable for product selection and quotation. You can provide the cable type, voltage rating, conductor material, cross-section, core number, insulation, application and required quantity.

Whether you need standard cables or specification-based production, our team can review your requirements and recommend suitable product options from our manufacturing range.

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept