For industrial control circuits that require flame-retardant protection and dependable signal transmission, Qiancheng Flame Retardant XLPE Copper Control Cable provides a practical wiring option. The XLPE insulation and flame-retardant sheath are designed for continuous service in applications involving industrial equipment, fire-protection systems, and new-energy installations. Standard cable specifications can be supplied for routine orders, with quotation, inspection, and customized production available for project-based and bulk procurement.

Product Models: ZR (ZA, ZB, ZC)-KYJV, ZR (ZA, ZB, ZC)-KYJVP, etc.

Flame Retardant XLPE Copper Control Cable is used in low-voltage control and signal circuits where flame propagation needs to be limited. The standard construction combines an oxygen-free copper conductor with XLPE insulation and a flame-retardant outer sheath, with solid or flexible conductor configurations available for different wiring requirements. Shielded and armored versions extend the range to installations where electromagnetic interference or mechanical protection also needs to be considered.

The XLPE insulation is specified for a maximum long-term operating temperature of 90 °C, while the cable is available in 450/750V configurations with multiple core counts and conductor cross-sections. Z(A, B, C) flame-retardant grades, shielding, armoring and special lengths can be selected according to the control circuit and laying conditions.

Flame Retardant XLPE Copper Control Cable

Product Specification, Dimensions and Technical Parameter Table

Parameter Category

Parameter Item

Technical Indicator

Supplementary Notes

Applicable Standard

National Standard

GB/T 9330, GB/T 19666

—

Basic Electrical Parameters

Rated Voltage

450/750V

Dedicated for low-voltage control and equipment signal transmission

Conductor Specification

Conductor Material

99.99% high-purity oxygen-free copper

Class 1 solid rigid conductor & Class 5 stranded flexible conductor

Conductor Specification

Standard Conductor Cross-section

0.75, 1.0, 1.5, 2.5, 4, 6 mm²

—

Conductor Specification

Standard Core Series

2, 3, 4, 5, 7, 10, 14, 19, 24, 37, 61 cores

Custom production for special core counts is supported

Cable Structural Material

Insulation Material

XLPE Cross-linked Polyethylene

Long-term operating temperature: 90 °C; short-term overload tolerance: 130 °C

Cable Structural Material

Sheath Material

Flame-retardant PVC or polyethylene (polyolefin)

Obvious self-extinguishing property to restrain flame spread

Flame-retardant Performance

Flame-retardant Grade

Optional Z(A, B, C)

Meets bundled flame-retardant requirements (A, B, C) specified in GB/T 19666

Electrical Performance Indicators

Finished-product Withstand-voltage Test

3000 V/5 min, no breakdown

100 % full-item inspection before delivery

Environmental Operating Parameters

Long-term Operating Temperature

Max. 90 °C

20 °C higher temperature-resistance than PVC cables; aging rate reduced by 65%

Environmental Operating Parameters

Minimum Laying Temperature

≥0 °C

Custom cold-resistant version allows direct construction at -30 °C

Laying Dimension (Minimum Bending Radius)

Unarmored ZR-KYJY/ZR-KYJYR

≥6 × cable outer diameter

For cable trays, indoor conduit routing and fixed wiring in cable trenches

Laying Dimension (Minimum Bending Radius)

Shielded flame-retardant ZR-KYJYP

≥8 × cable outer diameter

Copper-braided shielding coverage ≥80 % for anti-electromagnetic-interference performance

Laying Dimension (Minimum Bending Radius)

Armored flame-retardant ZR-KYJV22 or ZR-KYJY23

≥12 × cable outer diameter

Double-layer steel-tape armor; suitable for direct burial, rodent-proof and compression-resistant

Optional Derivative Models

Upgraded Functional Versions

Shielded type, steel-tape armored type, WDZ low-smoke flame-retardant type

For high-occupancy sites such as tunnels, hospitals and shopping malls

Supply Dimension Parameters

Standard Delivery Length

Customizable per user requirements

Custom cutting for any length; length tolerance ±0.5 %

Supply Dimension Parameters

Core Identification

Multi-colored cores with green-yellow earthing core

Easy on-site core identification to reduce construction errors

Supply Dimension Parameters

Packaging

Plastic film wrapping + plastic reel / fumigated wooden reel

Fumigated wooden reels for export orders with complete test reports attached

Construction and Performance

1. XLPE Insulation for Elevated-Temperature Control Wiring

The insulation system is based on cross-linked polyethylene rather than conventional PVC insulation. According to the supplied specifications, the XLPE layer has a maximum long-term operating temperature of 90 °C and a short-term overload tolerance of 130 °C. This makes the construction appropriate for control equipment and electrical installations where the cable may experience higher operating temperatures.

2. Copper Conductors for Control and Signal Circuits

The conductor specification covers 99.99% high-purity oxygen-free copper, with Class 1 solid conductors and Class 5 stranded flexible conductors available. The choice between rigid and flexible construction can be matched to the wiring method, terminal arrangement and installation space.

3. Flame-Retardant Sheath and Optional Protection

The outer sheath can be flame-retardant PVC or polyethylene (polyolefin), with Z(A, B, C) flame-retardant grades available. Shielded ZR-KYJYP and armored ZR-KYJV22 or ZR-KYJY23 configurations address additional installation requirements. Shielding is relevant where electromagnetic interference needs to be controlled, while steel-tape armor provides mechanical protection for specified laying conditions.

Flame Retardant XLPE Copper Control Cable

Choosing the Cable Configuration for the Installation

The appropriate construction depends on more than conductor size. Core quantity should match the number of control or signal circuits, while the conductor class should correspond to the installation method. For cable trays and indoor fixed wiring, an unarmored construction may be sufficient. Shielded versions can be considered for circuits affected by electromagnetic interference, while armored versions are intended for installations where the cable is exposed to mechanical pressure or direct-burial conditions.

For projects requiring reduced smoke and halogen characteristics, the available WDZ low-smoke flame-retardant version should be specified separately. Minimum bending radius also needs to be considered during routing: the supplied data lists ≥6 times the cable outer diameter for unarmored versions, ≥8 times for the shielded version and ≥12 times for the armored versions.

Typical Applications

1. Fire-Protection and Building Control Systems

Flame-retardant XLPE control cables can be incorporated into low-voltage control circuits for fire-protection equipment, building automation and related electrical systems. Core quantity and conductor size should be matched to the control equipment and circuit arrangement rather than selected only by overall cable diameter.

2. Photovoltaic and Energy-Storage Equipment

Control cabinets, inverter-related equipment and energy-storage systems may contain multiple low-voltage signal and control circuits within a confined installation area. XLPE insulation provides a higher specified operating-temperature range than the PVC control cables commonly used for lower-temperature applications, subject to the actual cable specification and operating conditions.

3. Industrial Automation and Process Equipment

The cable range can be used for control circuits associated with motors, pumps, fans, machine tools, PLC cabinets and other industrial equipment. Flexible conductor versions are useful where routing requires greater cable flexibility, while shielded constructions can be considered for signal circuits exposed to electromagnetic interference.

4. Underground Utility and Infrastructure Installations

Armored ZR-KYJV22 and ZR-KYJY23 configurations provide an option for installations requiring additional mechanical protection, including specified direct-burial applications. Unarmored versions can be used in cable trays, indoor conduits and cable trenches where mechanical protection is already provided by the installation method.

5. Power Equipment and Export-Oriented Projects

For substations, power plants, electrical equipment and overseas projects, the required cable specification should be confirmed against the project standard, voltage class, installation method and documentation requirements. Product documentation, test records and reel packaging can be arranged according to the delivery requirements of the project.

Flame Retardant XLPE Copper Control Cable

Technical Verification Before Ordering

For a control-cable project, the most useful information to confirm before production is the required voltage, conductor class, cross-section, number of cores, flame-retardant grade and laying environment. Shielding or armoring should be specified when electromagnetic interference or mechanical protection is part of the installation requirement.

The supplied technical data covers 0.75–6 mm² conductor cross-sections and standard core configurations from 2 to 61 cores. Delivery length can be customized, while the cable identification uses multi-colored cores with a green-yellow earthing core. For export orders, packaging can include plastic reels or fumigated wooden reels according to shipping requirements.

FAQ

1. What standards are specified for this cable?

The supplied product specification lists GB/T 9330 and GB/T 19666 as the applicable national standards. If a project requires additional certification, test reports or export documentation, the required document list should be confirmed before production.

2. What temperature range is specified for the XLPE insulation?

The technical data specifies a maximum long-term operating temperature of 90 °C and a short-term overload tolerance of 130 °C. The standard minimum laying temperature is ≥0 °C, while a cold-resistant version is listed for direct construction at -30 °C.

3. What conductor sizes and core configurations are available?

Standard conductor cross-sections are 0.75, 1.0, 1.5, 2.5, 4 and 6 mm². Standard core configurations include 2, 3, 4, 5, 7, 10, 14, 19, 24, 37 and 61 cores, with special core counts available for custom production.

4. When should a shielded or armored version be specified?

Shielded ZR-KYJYP can be considered when the control circuit requires electromagnetic-interference protection. Armored ZR-KYJV22 or ZR-KYJY23 is intended for laying conditions where additional mechanical protection is required, including specified direct-burial applications. The bending-radius requirements differ between these constructions.

5. What should be confirmed for a project quotation?

Provide the required model, conductor cross-section, core quantity, approximate length, laying method and any shielding, armoring, low-smoke or cold-resistant requirements. For export orders, destination, reel requirements and required technical or inspection documents should also be confirmed.

6. Can the cable be supplied in customized lengths?

Yes. The supplied specification lists customizable delivery lengths with a stated length tolerance of ±0.5%. Special core counts and functional configurations can also be discussed according to the project requirements.

 