Products
Light Flexible Rubber Cable for Coal Mine
  • Light Flexible Rubber Cable for Coal MineLight Flexible Rubber Cable for Coal Mine
  • Light Flexible Rubber Cable for Coal MineLight Flexible Rubber Cable for Coal Mine
  • Light Flexible Rubber Cable for Coal MineLight Flexible Rubber Cable for Coal Mine

Light Flexible Rubber Cable for Coal Mine

Light Flexible Rubber Cable for Coal Mine (Model MYQ-0.3/0.5kV), manufactured by China Qiancheng, is a special cable tailored for light-duty mobile power supply scenarios in underground coal mines. Manufactured in strict compliance with mining standards, it features excellent flexibility, wear resistance, flame retardancy and moisture-proof performance. Well-recognized in the market, it is an affordable industrial-mining cable. Factory-direct pricing is available, and custom quotations can be provided on demand to fully meet procurement requirements for various coal-mine projects.

Product Model: MYQ, 0.3/0.5kV

Light Flexible Rubber Cable for Coal Mine by China Qiancheng is suitable for humid and narrow underground mobile power-supply environments in coal mines, mostly used for underground lighting and power supply of small-size equipment. With years of experience in mining cable manufacturing, the brand owns independent production lines and quality-inspection laboratories. Products are fully certified with traceable test data, eliminating non-standard and inferior products. 

Light Flexible Rubber Cable for Coal Mine

Product Specification, Dimensions and Technical Parameter Table

Parameter Category

Parameter Item

Technical Indicator

Structure Configuration

Conductor Material

High-purity oxygen-free copper, multi-strand stranded flexible conductor, flexible and bending-resistant

 

Conductor Cross-section

1.0mm²~2.5mm²

 

Insulation Layer

Special rubber insulation, flexible and compression-resistant

 

Outer Sheath

Light-duty rubber sheath, wear-resistant, oil-resistant, lightweight and flexible

 

Core Specification

2-12 cores, optional

Electrical Performance

Rated Voltage

0.3/0.5kV

 

Insulation Resistance at 20℃

≥100 MΩ·km

 

Power-frequency Withstand Voltage

2.0 kV, no breakdown after 5-minute voltage endurance

 

DC Conductor Resistance

Meets requirements of MT 818 or GB/T 12972 standard

Flame-retardant Performance

Flame-retardant Grade

Complies with MT 386 mining flame-retardant standard; self-extinguishes upon removal of flame.

Advantages Compared with Peer Products

Common light-duty mining cables may show differences in sheath durability, conductor resistance, flexibility, flame-retardant performance and overall procurement cost. China Qiancheng Light Flexible Rubber Cable for Coal Mine is developed around these practical requirements, with attention to conductor material, stranded construction and rubber sheath performance. Product evaluation can be based on measurable electrical, mechanical and flame-retardant test results rather than appearance or nominal specifications alone.

Wear and Tear Resistance:

The sheath is required to withstand repeated contact and movement during underground installation and equipment operation. The use of XH03A rubber sheath compound provides a construction focused on flexibility, wear resistance and protection against mechanical damage. For applications involving frequent movement, actual wear performance should be verified according to the applicable test method and working conditions.

Conduction Stability:

Conductor material and stranding directly affect DC resistance and heat generation during continuous operation. The cable uses high-purity oxygen-free copper with multi-strand construction, while conductor resistance for the 1.0mm² to 2.5mm² specifications is controlled according to the applicable national standard requirements. This provides a measurable basis for checking electrical performance during production and inspection.

Flame-retardant and Moisture-related Performance:

Underground coal-mine environments can involve humidity, dust and restricted ventilation, making insulation and sheath condition important during cable selection. The rubber construction is intended to support moisture resistance and flame-retardant performance. Where mining safety or flame-retardant certification is required, the corresponding certificate and test report should be checked against the actual cable specification.

Cost and After-sales Considerations:

Procurement cost should be evaluated together with specification consistency, technical support and required documentation. China Qiancheng supplies the cable directly and can provide specification-based quotations and technical information according to project requirements, helping manufacturers, contractors and distributors compare the required configuration before placing bulk orders.

Core Product Selling Points

For light-duty underground coal-mine power-supply applications, the product combines flexible conductor construction, rubber sheath protection and mining-related performance requirements. The main points below focus on characteristics that can be checked against the selected specification and application conditions.

1. Flexible construction for mobile operation:

Fine-stranded copper conductors improve cable flexibility and make routing easier where underground equipment is frequently moved or repositioned. A minimum bending radius of 6 times the outer diameter is specified for the applicable construction, and installation should remain within the stated mechanical limits.

2. Flame-retardant performance for underground applications:

Flame-retardant performance is an important consideration in confined underground working areas. The cable configuration can be evaluated according to the applicable mining safety requirements, flame-retardant grade and supporting test or certification documents rather than relying only on general product descriptions.

3. Moisture and environmental resistance:

The modified rubber sheath is intended for underground conditions involving humidity, dust and limited oil contamination. Its actual resistance to moisture, weak acid-alkali exposure and oil should be considered together with the specific working environment and applicable test requirements.

4. Multiple specifications for different equipment:

Common conductor sizes include 1.0mm², 1.5mm² and 2.5mm², with 2-core, 3-core, 4-core, 7-core and 12-core configurations available for different circuit arrangements. Specification selection should consider rated load, voltage, core requirements, installation method and movement conditions.

5. Documentation for project acceptance:

For mining projects with formal inspection or acceptance requirements, product documentation may include quality-inspection records, safety-related certificates, factory acceptance documents and relevant test data. The required documents should correspond to the actual model, specification and applicable project requirements.

Light Flexible Rubber Cable for Coal Mine

Wide Application Scenarios

Light Flexible Rubber Cable for Coal Mine is applicable to all 0.3/0.5 kV low-voltage light-duty mobile power-supply conditions in underground coal mines. Practical cases cover major mining areas including Shanxi, Shaanxi, Henan and Shandong. Detailed application scope is listed below:

Light Flexible Rubber Cable for Coal Mine

· Underground roadway lighting systems: Mainly for power supply of mobile lighting devices in main roadways, auxiliary roadways and tunneling working faces of underground coal mines. Lightweight and easy-to-install with good drag resistance, it adapts to daily roadway maintenance and relocatable wiring, and is widely used in mine lighting renovation projects.

· Supporting for small conveying equipment: Suitable for interlock control circuits and auxiliary power-supply lines of underground belt conveyors and small-size scraper conveyors. Flexible and durable, Light Flexible Rubber Cable for Coal Mine works reliably with equipment vibration and relocation to guarantee stable equipment operation.

· Underground control and signal equipment: Used for power connection of mining sensors, alarm devices, communication signal equipment and small-size control boxes. Stable insulation and strong anti-interference performance ensure accurate underground signal transmission and equipment control.

· Temporary engineering and maintenance operations: Applied to temporary power-supply lines for underground coal-mine construction, equipment maintenance and roadway renovation. Lightweight, easy-to-store and quick-to-deploy with high safety factor, it perfectly fits short-term mobile power-supply scenarios.

· Underground supporting for non-coal mines: Also applicable for light-duty mobile power supply and signal transmission in metal mines and non-metal mines under equivalent working conditions with high universality.

FAQ

1. What’s the model and standard of this mining light rubber flexible cable?

The model is MYQ-0.3/0.5kV, manufactured strictly in accordance with MT/T 818.9-2009 standard for coal mine cables.

2. What cross-section and core options do you supply for MYQ cable?

Available cores: 2/3/4/7/12 cores; conductor cross-section: 1.0mm², 1.5mm², 2.5mm². Complete size parameters including insulation thickness, sheath thickness, outer diameter and weight are provided in our product spec sheet.

3. What are the main application scenarios of MYQ light mining cable?

It is designed for underground coal mine low-voltage mobile power supply, including tunnel lighting, small conveyor interlock control circuits, underground signal sensors, temporary maintenance power lines, also applicable to non-coal metal mines with similar working conditions.

1. What advantages does your cable have over ordinary similar mining cables?

2. Adopt modified nitrile rubber sheath, over 8000 times abrasion resistance, no cracking under frequent dragging;

3. High-purity oxygen-free copper conductor, stable resistance without overheating;

4. Flame retardant & moisture-proof, self-extinguishing after leaving fire;

5. Ultra-flexible, minimum bending radius only 6 times cable outer diameter;

6. Factory direct supply with competitive price and complete certification documents.

7. What temperature and bending requirements should be followed during installation and use?

Long-term max working temperature of conductor is 65℃; operating environment temperature range: -20℃ ~ +45℃, laying ambient temperature not lower than 0℃; minimum bending radius shall not be less than 6 times the finished cable outer diameter.

4. What certificates can you provide for mine engineering acceptance and export customs clearance?

We can supply MA safety certificate, factory inspection report, third-party test report, product certificate of conformity, complete parameter data sheet and export commercial documents to support mine acceptance and customs clearance.

 

Send Inquiry
Contact Info

Looking for the right cable for a project or application? Send your requirements to Qiancheng Cable for product selection and quotation. You can provide the cable type, voltage rating, conductor material, cross-section, core number, insulation, application and required quantity.

Whether you need standard cables or specification-based production, our team can review your requirements and recommend suitable product options from our manufacturing range.

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept